JL3KH6 Job Link® System Charge and Air Kit

JL3KH6

Overview

  • Directly connects to mobile device with Job Link System App

  • Fast accurate temps with new Rapid Rail technology

  • Pressures auto calibrate at any elevation

  • Great for critically charged systems

  • Stabilizes in under 5 seconds

  • Configurable psychrometers with flexible probe and sliding magnet

  • Beeper and LED indicate accurate connection

  • Rapid Rail™ sensor uses pipe to complete circuit so ambient conditions don’t affect the measurement

  • Narrow jaw connects in tight spaces and on irregular pipe shapes

  • Up to 1000’ wireless signal

    •     Powerful enough to go through most walk-in coolers and freezers

    •     Directly transmits to your mobile device

  •    45° angled fitting easily connects in tight spaces

  •     Pressure sensors are accurate at any elevation

  •     Calibrates automatically when powered on

  • A2L Compatible

  • Includes:

    • 2 x JL3PC Job Link Premium Pipe Clamp Probes

    • 2 x JL3PR Job Link Pressure Probes

    • 2 Job Link Psychrometer Probes

    • ANC18 Protective Case

    • 2 x AAA Batteries Per Probe (8 Total)

Specifications

  • Job Link Pressure Probe – JL3PR

    • Connector Type: 45° Standard 1/4” NPT female flare

    • Best Accuracy: ±1 psig (±7 kPa)

    • Measurement Range: 0 to 580 psig (0 to 4000 kPa)

    • Maximum Overload: 800 psig (5500 kPa)

    • Water Resistant: Designed to IP55

  • Job Link Premium Pipe Clamp Probe – JL3PC

    • Pipe Compatibility: Electrically conductive 1/4” to 1 3/8” (6.4mm to 34.9mm) dia.

    • Accuracy: ±1°F (±0.6°C)

    • Measurement Range: -50°F to 257°F (-46°C to 125°C)

    • Stabilization Time: Three seconds typical

    • Measurement Feedback: Beeper and LED

    • Water Resistant: Designed to IP55

    • Patent: 10,365,165

  • Job Link Flex Psychrometer Probe – JL3RH

    • Flexible Probe:    0.36” (9mm) diameter, 9.25” (235mm) length

    • Best Accuracy:    ±1°F (±0.6°C) ±2.5 %RH

    • Measurement Range:    -40°F to 250°F (-40°C to 121°C) 0 %RH to 100 %RH